Text commands for the FMB120 SMS Commands
لتفعيل وبرمجة مختلف الأجهزة والحصول على برنامج التتبع تواصل معنا واتساب: 966570960313+ ٍSystem Parameters/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 138 Uint8 0 0 8 1 – Ignition Movement source 2 – Accelerometer 4 – GNSS 8 – CAN Speed 133 Uint8 0 0 1 0 – GNSS Speed Source 1 – OBD / CAN 106 Uint8 1 0 1 0 – Disable Static navigation 1 – Enable 112 Uint8 1 0 3 1 – Movement Static navigation source 2 – Ignition 3 – Movement and Ignition 107 Uint8 2 0 2 0 – After Position Fix Send/Save records without TS 1 – Always 2 – After Time Sync 108 Uint8 1 0 1 0 – Disable LED Indication 1 – Enable 109 Uint8 10 1 15 0 – Undefined GNSS source 1 – Beidou only 2 – Glonass only 3 – Glonass and Beidou not allowed 4 – Galileo only 5 – Galileo and Beidou 6 – Galileo and Glonass 7 – Galileo, Glonass and Beidou not allowed 8 – Gps only 9 – Gps and Beidou 10 – Gps and Glonass 11 – Gps, Glonass and Beidou not allowed 12 – Gps and Galileo 13 – Gps, Galileo and Beidou 14 – Gps, Galileo and Glonass 15 – Gps, Galileo, Glonass and Beidou and not allowed 110 Uint8 0 0 1 0 – On need Battery charge mode 1 – After ignition on 113 Uint8 0 0 1 0 – Codec 8 Data Protocol 1 – Codec 8 Extended 135 Uint8 0 0 1 0 – DIN2/AIN1 Input mode 1 – Ground Sense Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 102 Uint8 2 0 4 0 – Disable Sleep settings 1 – GPS sleep 2 – Deep sleep 3 – Online Deep sleep 4 – Ultra Deep sleep 6 – Power Off sleep (only for FMB965) 103 Uint16 1 1 3000 Minutes Timeout Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 101 Uint8 4 1 14 1 – DIN 1 Ignition settings 2 – Accelerometer 3 – Digital Input or Accelerometer 4 – Power Voltage 5 – Digital Input or Power Voltage 6 – Accelerometer or Power Voltage 7 – Digital Input, Accelerometer, or Power Voltage 8 – Engine RPM 9 – Digital Input or Engine RPM 10 – Accelerometer or Engine RPM 11 – Digital Input, Accelerometer or Engine RPM 12 – Power Voltage or Engine RPM 13 – Digital Input, Power Voltage or Engine RPM 14 – Accelerometer, Power Voltage or Engine RPM 104 Uint16 30000 0 30000 mV High voltage 105 Uint16 13200 0 29999 mV Low voltage Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 19001 Uint16 5 1 60 Seconds Movement Start Delay 19002 Uint16 60 5 300 Seconds Movement Stop Delay Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 900 Uint8 1 0 3 0 – Gps only Synchronization settings 1 – NITZ and NTP 2 – NTP 3 – NITZ 901 Uint8 0 0 24 Hours NTP Resync 902 Char “avl1.teltonika.lt” 0 55 String NTP server 1 903 Char “pool.ntp.org” 0 55 String NTP server 2 Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 169 Uint8 2 0 2 0 – Disabled Accelerometer Auto Calibration 1 – Once 2 – Continuous 170 Uint8 1 0 1 0 Disabled Gravity Filter 1 Enabled FMB120 System Sarameters SMS Commands ٍGPRS Parameter/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 1000 Uint32 300 30 259200 Seconds Open link timeout 1001 Uint16 30 5 300 Seconds Response timeout 1002 Uint8 0 0 1 0 – Newest Sort by 1 – Oldest 1003 Uint16 0 0 300 Seconds Network ping timeout Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2000 Uint8 1 0 1 0 – Disable GPRS context 1 – Enable 2001 Char “” 0 32 String APN 2002 Char “” 0 32 String APN username 2003 Char “” 0 32 String APN password Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2004 Char “” 0 55 String Domain 2005 Uint16 0 0 65535 Number Port 2006 Uint8 1 0 1 0 – TCP Protocol 1 – UDP Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2010 Uint8 0 0 3 0 – Disable Backup Server Mode 1 – Backup 2 – Duplicate 3 – EGTS 2007 Char “” 0 55 String Backup Server Domain 2008 Uint16 0 0 65535 Number Backup Server Port 2009 Uint8 0 0 1 0 – TCP Backup Server Protocol 1 – UDP Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 13003 Uint8 1 0 1 0 – Disable FOTA WEB Status 1 – Enable 13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain 13001 Uint16 5000 0 65535 Number FOTA WEB Port 13002 Uint16 720 30 65535 Number FOTA WEB Period GPSR Parameters/FMB120 SMS Commands SMS-Call Settings/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3000 Uint8 0 0 1 0 – Disable Allow SMS data sending 1 – Enable 3001 Char “” 0 16 String Data Send Number Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3003 Char “” 0 5 String Login 3004 Char “” 0 5 String Password 3006 Uint16 UTC+00:00 UTC-12:00 UTC+13:00 Time zone SMS event Time Zone Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3005 Uint8 0 0 4 0 – Do nothing Incoming call action 1 – Hangup 2 – Report position 3 – Spy call 4 – Auto answer Parameter ID Parameter Type Default value Value range